11.0 Installing the Flue System:
Non-Masonry Timber Frame Cavity:
The heater must be flued to the outside via a 100mm diameter stainless steel flue that is
covered by a 150mm diameter liner. This must be installed in accordance with the
requirements of AS/NZS 5601.
The minimum flue length = 3.6m vertical height
It is important to check that you have all the necessary flue parts before beginning your
installation.
A standard timber flue installation should include the following components:
2 x G3001 –
150 x 1200mm
Galv Flue Liner
3 x G3000 –
100 x 1200mm
Flue
1 x 100409 –
150 x 1040mm
Galv Flue Liner
1 x 260020 –
100mm Clamping
Flue Sleeve
2 x G3003 –
Flue Liner Spacer Bracket
3 x G3005 –
Spider Bracket
1 x 100398 –
180mm Flue Sleeve
100408 - Angle
50x50x900 Flue
Bracing
1 x G3009 –
Flue Liner Joiner
IMPORTANT:
IF USING A 45º OFFSET KIT THERE MUST BE A MINIMUM OF
600MM FROM THE FIREPLACE TO THE FIRST OFFSET.