Escea IB600 Installation Manual

Browse online or download Installation Manual for Fireplaces Escea IB600. Escea IB600 Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
630184_4 IB Installation Manual NZ
IB1100, IB850, IB600 (Log Fire / Coal Fire)
Installation Manual
NEW ZEALAND EDITION
Important:
The appliance shall be installed in accordance with;
This installation instruction booklet
Local gas fitting regulations
Municipal building codes
Electrical wiring regulations
AS/NZS 5601 Gas installations
Any other relevant statutory regulations.
Must be installed by a qualified person
This appliance is not intended for use by young children or infirm persons unless they have been
adequately supervised by a responsible person to ensure that they can use the appliance safely.
Young children should be supervised to ensure that they do not play with the appliance.
Manufactured by: Escea Ltd, PO Box 5277 Dunedin NZ, Ph: +64 3 478 8220, email: info@escea.co.nz
For contact details of your local escea distributor or dealer please visit www.escea.co.nz
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Installation Manual

630184_4 IB Installation Manual NZ IB1100, IB850, IB600 (Log Fire / Coal Fire) Installation Manual NEW ZEALAND EDITION Importa

Page 2 - WARNING:

630184_4 IB Installation Manual NZ 10 10.0 Power Supply: Whilst the cavity is being created consideration should be given to appropriate location o

Page 3

630184_4 IB Installation Manual NZ 11 11.0 Installing the Flue System: Non-Masonry Timber Frame Cavity: The heater must be flued to the outside via

Page 4 - IB850 & IB1100

630184_4 IB Installation Manual NZ 12 12.0 Flue Assembly Secure the Flue spacer bracket (G3003)

Page 5

630184_4 IB Installation Manual NZ 13 12.1 Installing the Flue Terminal Cut the flue termination to the height specified on the attached “Flue po

Page 6

630184_4 IB Installation Manual NZ 14 12.2 The top of the flue must be capped with an appropriate anti down draft cowl. Note: As per national standa

Page 7 - Creating the Cavity:

630184_4 IB Installation Manual NZ 15 FROM AS/NZS 5601, please ensure compliance to all other relevant sections of this code. 2.6.13 FLUE TERMINALS

Page 8

630184_4 IB Installation Manual NZ 16 FLAT ROOFS WITH NO PARAPET STRUCTURE CLOSE TO FLUE TERMINALFLUE CLOSE TO PARAPET MULTIPLE STRUCTURES (Envelope

Page 9

630184_4 IB Installation Manual NZ 17 12.4 Fixing the Flue to the Cavity A length of Angle should be attached to the inside of the timber frame ca

Page 10

630184_4 IB Installation Manual NZ 18 13.0 Masonry Cavity and Chimney: The heater can be flued with 100mm flexible aluminum ducting in accordance w

Page 11

630184_4 IB Installation Manual NZ 19 14.3 It is recommended that a gas isolating valve be installed as close to the regulator on the

Page 12

630184_4 IB Installation Manual NZ 2 Note: THERE ARE A FEW THINGS TO CONSIDER BEFORE INSTALLATION  Cavity Dimensions, Clearances and fitting the

Page 13 - 25 - 30mm

630184_4 IB Installation Manual NZ 20 15.3 Attach the Top-Rear: Attach the top-rear panel to the Sides and Rear panels, with the flanges of the To

Page 14 - 200mm min

630184_4 IB Installation Manual NZ 21 17.0 Gas Fireplace Installation: Attached to the base of the Zero Clearance Kit are guide rails. The inside e

Page 15

630184_4 IB Installation Manual NZ 22 18.0 Attaching the Flue to the Fireplace: Once the gas fireplace has been inserted into the ZCK

Page 16 - Prohibited

630184_4 IB Installation Manual NZ 23 20.0 Fixing the Heater to the Base and Wall: There are several ways that the heater can be fi

Page 17

630184_4 IB Installation Manual NZ 24 21.0 Placing the fuel bed: After replacing the firebox (if removed in 17.1) the fuel bed media can now be pl

Page 18

630184_4 IB Installation Manual NZ 25 IB850 Log & Template Position 4) Line up some of the coals that have been supplied with

Page 19 - Split plug as indicated

630184_4 IB Installation Manual NZ 26 21.2 Locating the Log Set for IB1100: 1) Remove packaging from around log sets 2) Place 2 x rear logs (long

Page 20

630184_4 IB Installation Manual NZ 27 21.4 Log or Coal Replacement: The fire unit should never be used with broken logs or coals. Turn

Page 21

630184_4 IB Installation Manual NZ 28 Step 6: Remove and discard the front and middle burners as described in section 24.1 and 24.2 of this man

Page 22

630184_4 IB Installation Manual NZ 29 Step 7: Attach the Log Template at the left hand side, using the existing screw which is holding the middle

Page 23

630184_4 IB Installation Manual NZ 3 Contents: Section:  Product Description 1.0  Creating the Cavity

Page 24

630184_4 IB Installation Manual NZ 30 24.0 Gas Type Conversion: Your gas fire has been supplied with the necessary parts for gas conversion. F

Page 25

630184_4 IB Installation Manual NZ 31 24.5 Step 5: If changing from LPG to NG, slide the supplied burner collar onto the burner tubes of both

Page 26

630184_4 IB Installation Manual NZ 32 25.0 Checking Operating Pressure: WARNING: The regulator that is supplied with the fire MUST NOT BE REMOVED.

Page 27 - Rear Log Retainer

630184_4 IB Installation Manual NZ 33 26.1 Fitting the Fascia Panels: To avoid scratches or knocks to the fascia panels of this heater they must be

Page 28

630184_4 IB Installation Manual NZ 34 26.2 When installing a 4 sided fascia ensure that the clips that the outer fascia screw into are at the bottom

Page 29

630184_4 IB Installation Manual NZ 35 28.0 Normal Operating Sounds and Smells; Note: Each time the fire is lit from cold the glass may fog up with

Page 30 - Remove Screws

630184_4 IB Installation Manual NZ 36 29.0 Installation Check List: 1 Ensure there is adequate ventilation in the area the appliance

Page 31

630184_4 IB Installation Manual NZ 37 30.0 WARRANTY TERMS & CONDITIONS: Provided that the Product is installed as per ESCEA’s Installation Man

Page 32 - Beckley

630184_1 IB Service Manual NZ 11 Wiring Diagram:

Page 33

630184_1 IB Service Manual NZ 10 Annual service procedure: 1. Isolate power to fire. 2. Remove front glass and clean inside of glass. 3. Remove lo

Page 34 - Top lip

630184_4 IB Installation Manual NZ 4 1.0 Product Description: The Escea IB1100, IB850 and IB600 gas fires are designed to be built into a cavity. Th

Page 35 - WITH THE GLASS REMOVED

630184_1 IB Service Manual NZ 9 Red auxiliary Button Replacing a Wireless Control: If the wireless control becomes lost or damaged, a new one can be

Page 36

630184_1 IB Service Manual NZ 8 Note: It is important that the flame rod & spark lead wires sit in this position in the electronic tray. Replacin

Page 37

630184_1 IB Service Manual NZ 7 Removing or Cleaning Fan As part of regular service procedure, it is recommended that the fan is removed for cleaning

Page 38 - Wiring Diagram:

630184_1 IB Service Manual NZ 6 Checking Operating Pressure: This is done at the regulator located at the front RH corner of the appliance. This is b

Page 39 - Annual service procedure:

630184_1 IB Service Manual NZ 5 Cleaning the Log Set and Glass: NEVER RUB THE FASCIA. The outside of the fascias must only be cleaned with a clean d

Page 40 - IB600 IB850 & IB1100

630184_1 IB Service Manual NZ 4 Or Draught Diverter Sensor Trip The bimetallic snap disk mounted on the hood of the draught diverte

Page 41 - & IB1100

630184_1 IB Service Manual NZ 3 Error Codes: This gas fire has been designed to show error codes to help explain and identify any fault situation tha

Page 42 - Removing or Cleaning Fan

630184_1 IB Service Manual NZ 2 Contents: Page: Error Codes 3 Cleaning the Log Set and Glass 5 Checking Ope

Page 43 - Checking Operating Pressure:

630184_1 IB Service Manual NZ IB1100, IB850 and IB600 (Log Fire / Coal Fire) Service Manual NEW ZEALAND EDITION Important 

Page 44

630184_4 IB Installation Manual NZ 5 1.2 Product Dimensions IB850 IB600 Velo (3 sided) Velo (4 sided) A

Page 45

630184_4 IB Installation Manual NZ 6 IB1100 Velo (3 sided) Velo (4 sided) Quadrato Rado A 1360mm

Page 46 - Error Codes:

630184_4 IB Installation Manual NZ 7 CAB2.0 Creating the Cavity: The dimensioned drawing below shows the size of the opening that must be created to

Page 47

630184_4 IB Installation Manual NZ 8 IB850 & IB1100: Therefore excess = 43MJ/hr - 25.2MJ/hr = 17.8MJ/hr = 4.94kW Wall Vent Opening = 4.94 x 5

Page 48 - Service Manual

630184_4 IB Installation Manual NZ 9 30030150100200Maintain a 30mm clearance around the fascia to ensure ease of fascia removal. NB: No clearance is